Description
Protection class
IP45
Operating voltage
12 V DC
Power consumption
7.2 W
Power consumption standby
1 W
Flow pressure
10-1000 kPa
Maximum cold water temperature
25 °C
Flush volume Factory setting for cistern (l)
6 and 3 l
Large flush volume Setting range for cistern
4 / 4.5 / 6 / 7.5 l
Small flush volume Setting range for cistern
2-4 l
Calculated flow rate
0.11 l/s
Minimum flow pressure for calculation flow
50 kPa
Flushing capacity per solenoid valve
4 l/min
Interval flushing Factory setting
72 h
Interval flushing time Factory setting
180 s
Maximum flush volume per day and solenoid valve
40 l
Minimum flush interval
24 h
For installation in part-high or room-high pre-wall installations
For installation in room-high installation walls
For installation in part-height or room-height Geberit Duofix system walls
For wall-hung WCs with connection dimensions according to DIN EN 33:2011-11
For wall-hung WCs with projection up to 62 cm
For 1-flush, 2-flush or flush-stop flushes
For floor constructions 0-20 cm
To prevent stagnation in drinking water pipes
Self-supporting powder-coated frame
Frame with 9 mm dia. drill holes for fastening in wooden post-and-beam construction
Frame prepared for supports for WC ceramics with small contact surface
Galvanised footrests
Footrests adjustable 0-20 cm
Footrests with slip resistance
Footplates rotatable
Footplate depth suitable for installation in U-profiles UW 50 and UW 75 and Geberit Duofix system rails
Connection bend can be mounted in various depth positions without tools, adjustment range 45 mm
Sound-insulated mounting of connecting elbow
Concealed cisterns with actuation from the front
Flush-mounted cistern with condensation water insulation
Immediate flushing possible with factory setting
Building protection for service opening protects against moisture and dirt
Construction protection for service opening can be cut to length
With empty pipe for water supply line for connection of Geberit AquaClean shower toilets
Mounting option for electrical connection
Flush programmes selectable (time or interval)
Compatible with Geberit SetApp
Operation and initial commissioning with Geberit SetApp
Protocols can be read out with Geberit SetApp
Potential-free fault indication via digital I/O
Built-in backflow sensor
Solenoid valve normally closed
One connection for cold water R 1/2", MF-capable, with blue protective cap, on top
Building protection for service opening
Connection set for WC, ø 90 mm
Connection bend 90° of PE-HD, ø 90 mm
2 protective plugs
2 threaded rods M12
Transition sleeve made of PE-HD, ø 90 / 110 mm
Solenoid valve unit with safety pin and flow limiter
Power supply unit 230 V / 12 V / 50 Hz with output cable length 5 m
Control unit
Fixing material