Description
Protection class
IP45
Rated voltage
110-240 V AC
Mains frequency
50-60 Hz
Operating voltage
4.5 V DC
Power consumption
< 0.5 W
Flow pressure
100-800 kPa
Maximum test pressure water
1600 kPa
Maximum test pressure air / inert gas
300 kPa
Relative humidity
< 100 %
Maximum water temperature
30 °C
Flow rate at 100 kPa without flow limiter
0.3 l/s
Flow rate at 100 kPa with flow limiter
0.18 l/s
Calculated flow rate
0.23 l/s
Minimum flow pressure for calculation flow
100 kPa
Interval flush Setting range
1-168 h
Interval flush Factory setting
24 h
Interval flush time Setting range
3-180 s
Interval flush time Factory setting
5 s
Dwell time Setting range
3-15 s
Dwell time Factory setting
7 s
Flushing time Setting range
1-15 s
Flushing time Factory setting
7 s
For automatic flush triggering of urinals
For Geberit mounting elements for urinal with front actuation
For installation in shell kits for Geberit urinal flush controls (from year of construction 2009)
Cover plate with safety catch
Safe IR distance detection
IR sensor self-adjusting
Water-saving hybrid mode adjustable
Dynamic flush time adjustment
Adjustable pre-rinse
Convertible to operation with lid urinal
Power supply via mains connection
Power supply unit with LED display
Valve closing function in case of power failure
Functions can be set and queried with Geberit service mobile phone
Device settings and operation with mobile device via integrated Bluetooth® interface
Compatible with Geberit Control App
Wired connectivity with Geberit Gateway via GEBUS converter
Wirelessly networkable with Geberit Gateway via Bluetooth®
Compatible with Geberit Connect
Flush trigger can be deactivated
Flush volume can be reduced to 0.5 l per flush via throttle screw of the body kit
Fitting group II according to DIN 4109
Type 30 cover plate with IR window
Infrared control, pre-mounted on mounting frame
Solenoid valve
Power supply unit
Fixing material